Workload And Tuning

Start by measuring the busiest tick your host needs to support. In a strategy scene with 1,024 registered actors, a quiet frame and a crowded frame can have very different costs. The difference depends on how many actors are awake, how many contacts they create, how many partitions they cover, and which host work runs that tick.

Set a time budget first. Then replay the same scene while changing one setting at a time, checking both timing and the resulting physics.

Set The Host Budget

The fixed interval in milliseconds is 1000 / tick rate. At 60 Hz it is 16.67 ms. If the host reserves 5 ms for work outside the measured scenario, the scenario has 11.67 ms available. Choose the reserve and the tolerated miss rate from the application's own latency requirements. For example, a 12 ms scenario frame fits the full 60 Hz interval but exceeds the 11.67 ms budget with that reserve.

flowchart TB
    accTitle: Example timing budget at 60 Hz
    accDescr: A 60 hertz tick lasts about 16.67 milliseconds. Reserving 5 milliseconds for other host work leaves 11.67 milliseconds for the scenario.
    Tick["60 Hz tick: 16.67 ms"] -->|"Reserve 5 ms for other work"| Budget["Scenario budget: 11.67 ms"]

Measure two windows on the target host:

  1. Physics step. Time Simulate() and LateSimulate() together, including the hooks and coroutines that execute inside them.
  2. Scenario frame. Also include ordered command application, actor registration and retirement, and scheduled queries. Reserve time only for host work outside this window.

Keep wall-clock measurements outside authoritative decisions. Preallocate sample buffers and record the frame and stage for each miss. During clean timing runs, defer replay hashes, metric aggregation, and output until after the timed window. Use a separate pass for expensive observation or profiling and compare its replay results with the timing control. Host lifecycle and diagnostics describe the available boundaries.

Describe And Replay The Workload

Record settings, runtime and package versions, hardware, initial state, and the ordered commands. Include quiet, sparse, and crowded frames, first activation, and repeated wake, spawn, retirement, and recovery. Keep local spacing and encounter density explicit when scaling the actor count.

Record Why it matters
Registered and peak awake bodies by mode and mobility A mostly sleeping population can have very different cost from an equally sized active one.
Local density, collider types and extents, covered partitions Large shapes or tighter cells can increase coverage even with steady actor count.
Candidate pairs, touching pairs, connected contacts, and islands Broad-phase work, retained contacts, and solver work can scale differently.
Query type, cadence, and candidate counts, plus CCD bodies and time-of-impact work A small number of scheduled or fast-moving actors can create their own bursts.
First-use and warmed median, p95, p99, maximum, and misses by stage A pooled percentile can hide an overloaded stage or a synchronized wake burst.

Verify replay and expected outcomes for each configuration. For example, check floor support, projectile stops, connected encounters, and ordered query hits. Changing a setting can legitimately change the trace. Check reproducibility within that setting and compare behavior against the intended physical bounds.

Compare Partition Cell Sizes

Start with cells that suit the collider extents and local spacing. Hold the scene bounds, commands, materials, and solver settings fixed. For a 3D scene with a floor, compare horizontal X/Z sizes while keeping Y fixed to separate horizontal coverage and candidate effects. Smaller cells can raise per-body coverage and lookup costs. Larger cells can increase candidate and contact work even when partition refresh gets cheaper. Measure both before choosing. Collision Broad Phase

Example Capture At 60 Hz

One 60 Hz synthetic strategy scene used pure 2D circles and boxes or pure 3D spheres and boxes, manual grounding, six discrete solver iterations, and CCD on the scheduled projectiles. The capture used a Windows x64 Core i7-9700K and .NET 10 Release. Each configuration pooled 20,480 measured frames from two fresh processes after four complete warmup cycles per process. The active scene used up to 32 awake actors per 256 registered actors. Capture protocol · Warmed frame results

Configuration Warmed scenario p99 Warmed misses of 16.67 ms
2D, 256 actors 1.08 ms 0 / 20,480
2D, 1,024 actors 3.81 ms 0 / 20,480
3D, 256 actors 3.75 ms 0 / 20,480
3D, 1,024 actors, X/Z 8 and Y 4 15.65 ms 9 / 20,480
3D, 1,024 actors, X/Z 16 and Y 4 12.28 ms 3 / 20,480

In the 1,024-actor 3D scene, 16-unit cells improved crowded warmed p99 from 15.96 to 12.66 ms and retained about 2.9 MiB more managed heap. Warmed frame results · Retained memory results

The first synchronized wake at 16 units missed 60 Hz in all six fresh-context comparisons, while the warmed wake bursts fit at both sizes. Four-unit cells missed every crowded frame in the short comparison. Keep 8 as the reference for this scene. Compare 16 if sustained crowd cost matters and first-use latency and memory fit your host budget. At the example 11.67 ms budget, both 1,024-actor 3D settings exceed the crowded p99 target. Fresh-context cell-size comparison

Tune One Policy At A Time

  • Awake population and density. Track the work created by simultaneous wakes and connected contacts. If the game permits staggered activation, replay the new command schedule and check response and gameplay timing. Keep sleeping and unregistered populations distinct in the capture.
  • CCD. Choose continuous modes for bodies whose motion needs a swept collision check. Verify supported shapes and motion, then compare fast-projectile or thin-obstacle cases against the intended stop positions and record time-of-impact work and iteration limits. Continuous Collision Detection
  • Grounding and solver iterations. Keep the baseline policy and iteration count fixed during capacity comparisons. To change either, pair frame costs with measurements of support, penetration, settling, drift, or joint error on the affected fixtures. Accept a setting only when it meets the host's physical error bounds and tick budget. Collision Response
  • Queries and shapes. Measure the actual cadence, filters, and geometry. Reuse caller-owned hit buffers and verify ordered results. Curved feature evaluation can cost time even when another feature wins or a candidate produces no contact. Count dispatch and expensive-path work before using observed final contacts to explain cost. Query Services

Compare Tick Rates And Solver Passes

Start with the default six PhysicsSettings.DiscreteSolverIterations. Compare settings on the same authored scene, keeping masses, geometry, materials, and commands fixed. At different tick rates, run for equal simulated time and apply disturbances at the same simulated times. Include settled support, repeated wake and recovery, and any drops or impacts your host expects. Use a fresh context for each run.

Measure the errors the scene must tolerate. For stacks, check both support interfaces, residual penetration, drift, and whether a body reaches an unintended surface. For jointed scenes, record anchor separation, limit error, and body displacement independently. A tip can move about a pinned root while its anchors remain close. For supported groups, verify that the group sleeps between disturbances and wakes together. Compare replay within each setting and use complete-step timings to check the host's reserved physics budget. Collision Response

Example Solver-Pass Comparison

In an eight-second 60 Hz pass sweep on a Windows x64 Core i7-9700K with .NET 10 Release, the same spatial fixtures produced these ranges of per-launch full-step p95 values after the first second. Duration quality measurements

Fixture 2 passes 6 passes 12 passes Physical result
Centered 100:1 top-loaded stack with repeated pulses 0.23–0.24 ms 0.31–0.32 ms 0.45–0.50 ms Both supports held, residual depth stayed within 1/16 unit, and both bodies woke on all three pulses.
Contact-free chain with a 100:1 heavy tip 1.59–1.66 ms 3.13–3.35 ms 5.49–6.55 ms At six and twelve passes, anchor gaps met the bounds and tip displacement stayed near 1.15 units, above the one-unit target.

Two passes also preserved the measured homogeneous heavy-bottom supports, while the sixteen-stack mixed-load control lost a support at that setting. The homogeneous sixteen-stack case exceeded 16.67 ms on every measured six-pass step. Raising the pass count can change which exact response paths execute, so cost can move in either direction. Measure representative load mixes before applying a setting to the whole context.

Six passes met the geometry and connected-wake checks for the matched planar and spatial ragdoll suite at 32 and 60 Hz. Two passes failed the supported planar wake check and several drop geometry checks. In the six-pass supported spatial control, four launches per rate had zero full-interval overruns, with worst steps of 21.53 ms at 32 Hz and 16.62 ms at 60 Hz. The 60 Hz result leaves about 0.04 ms before any additional host work. Measure the recovery frames and the host reserve when choosing a rate. Supported spatial ragdoll measurements

Check Save And Populate Continuation

For hosts that populate existing bodies from saves, record a checkpoint after real simulation steps. Exercise both free motion and awake support, and continue with the same ordered commands. Compare exact replay against a control with the same clock, registrations, retained pair history, and cache invalidation as the populated world. Also compare physical recovery against an uninterrupted run with warm contact impulses. Clearing warm impulses on population can change the active-contact trace, so check support and measure position, velocity, and rotation deltas over the continuation window. Serialization And Replay

Check Long-Session Memory

Run repeated equal-envelope churn in the same context. Record startup, warmup, and steady allocation separately from spawn and wake bursts. Track GC activity, registered objects, and active, retained, and pooled partitions. Compare retained managed memory after equal cooldown boundaries, after retirement, and after disposal in a separate pass with full collections outside timed frames. Record process working set separately because it includes runtime and native memory. A plateau applies to the measured envelope and duration. Repeat the comparison when actor policy, geometry, target hardware, or package versions change materially.